Resources

Documents for test engineers

Official datasheets, technical notes and a working glossary. Model-level figures are confirmed at quotation; the documents here describe the platform and the measurement classes.

All specifications quoted in these documents are typical, model-dependent.

Document library

Find the document by type

Files that can be published are linked directly. Documents that depend on your configuration are requested from an engineer, so you receive the revision that matches the order.

Find the document by type
Document typeWhat it containsAccessWhere to start
Model datasheetsCurrent-revision PDFs for cell, module, pack, chamber and all-in-one systems.PDF downloadBrowse datasheets
Compliance and certificatesISO 9001, CE and CNAS calibration credentials, with document availability.On requestSee the register
Manuals and quick-startOperation manuals, setup guides and first-run checks for the delivered system.On requestRequest a manual
Software and release notesBTS 9.1 capability, demo access and the update path for installed systems.Demo or on requestSee BTS 9.1 · Request a demo
Technical notesShort papers on range selection, sampling and regenerative discharge.On requestAsk for a note
Calibration recordsCertificate format, interval planning, as-found and as-left reporting.On requestSee calibration
PublicationsPeer-reviewed papers whose methods section names a NEWARE model, with a link to each DOI.Open listPublications (52)

Datasheets are published in English. Translated summaries and quotations are available through a regional partner on request. Older revisions are retrieved by model and serial number.

Datasheets

File centre — 29 official PDFs

Every datasheet in the library, grouped by platform. File size is read at build time; downloads open directly, with no form.

Cell testing system cabinet
Cell testing system cabinet
MGDW environmental chamber
MGDW environmental chamber

Cell-testing hardware from the NEWARE production line.

Cell & module testers 11

Cell & module testers
Model / documentFileRevEffective dateSizeDownload
BT-9562BT-9562.pdfR2025.032025-03-12298 KBDownload PDF
BTS-4008-5V20A-ABTS-4008-5V20A-A.pdfR2025.032025-03-12342 KBDownload PDF
BTS-4008Q-5V100mA-124BTS-4008Q-5V100mA-124.pdfR2025.032025-03-12234 KBDownload PDF
BTS-4008Q-5V12A-S1BTS-4008Q-5V12A-S1.pdfR2025.032025-03-12382 KBDownload PDF
BTS-4008Q-5V20A-SRBTS-4008Q-5V20A-SR.pdfR2025.032025-03-12652 KBDownload PDF
BTS-4008Q-5V30A-SRBTS-4008Q-5V30A-SR.pdfR2025.032025-03-12652 KBDownload PDF
BTS-4008Q-5V6A-S1BTS-4008Q-5V6A-S1.pdfR2025.032025-03-12354 KBDownload PDF
BTS-6001A-5V2000A-HBTS-6001A-5V2000A-H.pdfR2025.032025-03-12498 KBDownload PDF
BTS-6008A-5V300A-HBTS-6008A-5V300A-H.pdfR2025.032025-03-12497 KBDownload PDF
CA-4008n-1U-5VT-TCCA-4008n-1U-5VT-TC.pdfR2025.032025-03-12213 KBDownload PDF
CA-4032n-1U-T-TCCA-4032n-1U-T-TC.pdfR2025.032025-03-12181 KBDownload PDF

Chambers 12

Chambers
Model / documentFileRevEffective dateSizeDownload
WFB-220-20KWFB-220-20K.pdfR2025.032025-03-12131 KBDownload PDF
WFB-220-2KWFB-220-2K.pdfR2025.032025-03-12132 KBDownload PDF
WFB-500-2KWFB-500-2K.pdfR2025.032025-03-12133 KBDownload PDF
WFB-600-2KWFB-600-2K.pdfR2025.032025-03-12133 KBDownload PDF
WGDW-1000-40-2024WGDW-1000-40-2024.pdfR2025.032025-03-12352 KBDownload PDF
WGDW-150-20-2024WGDW-150-20-2024.pdfR2025.032025-03-12375 KBDownload PDF
WGDW-150-40-2024WGDW-150-40-2024.pdfR2025.032025-03-12375 KBDownload PDF
WGDW-225-2-40WGDW-225-2-40.pdfR2025.032025-03-12306 KBDownload PDF
WGDW-225-40WGDW-225-40.pdfR2025.032025-03-12375 KBDownload PDF
WGDW-225-70-2024WGDW-225-70-2024.pdfR2025.032025-03-12375 KBDownload PDF
WGDW-408-40WGDW-408-40.pdfR2025.032025-03-12374 KBDownload PDF
WHW-25L15CWHW-25L15C.pdfR2025.032025-03-12512 KBDownload PDF

All-in-one 6

All-in-one
Model / documentFileRevEffective dateSizeDownload
MHW-200-2024MHW-200-2024.pdfR2025.032025-03-12518 KBDownload PDF
MHW-25-16CHMHW-25-16CH.pdfR2025.032025-03-12589 KBDownload PDF
MIHW-100-2-160CH-JadeMIHW-100-2-160CH-Jade.pdfR2025.032025-03-12511 KBDownload PDF
MIHW-200-160CH-JadeMIHW-200-160CH-Jade.pdfR2025.032025-03-12458 KBDownload PDF
MIHW-300-80CHMIHW-300-80CH.pdfR2025.032025-03-12307 KBDownload PDF
WGDW-380L-2-40-8CHWGDW-380L-2-40-8CH.pdfR2025.032025-03-12243 KBDownload PDF
Which document answers which question
Document map by question
If you need… Start with Then confirm
Cell-channel accuracy and rangesBTS-4008Q series datasheetsCalibration certificate and uncertainty at quotation.
High-current single-cell testingBTS-6001A-5V2000A-HCurrent profile, cabling and cooling at quotation.
Internal resistance measurementBT-9562 impedance testerProbe selection and measurement frequency.
Pack voltage and regenerative feedbackResources overview + contactConfiguration-specific datasheet with the quotation.
Chamber volume and temperature rangeResources overview + contactConfiguration-specific chamber sheet.
Formation-line channel countBTS-4008Q channel datasheetsCabinet integration and handling layout at quotation.

White papers

Technical notes

Short papers on measurement decisions that change test outcomes. Each is available on request while the library is prepared for online publication.

White paperOn request

Choosing a current range for low-capacity cells

How four-range auto-ranging keeps resolution at microamp currents without sacrificing the 300 A range needed later in the same test programme.

Request via contact form — ask for the white paper.

White paperOn request

What sampling rate hides in fast-charge tests

Why 1000 Hz sampling and a ≤100 µs current response change the voltage trace you see during pulse charging — and what slower systems miss.

Request via contact form — ask for the white paper.

White paperOn request

Regenerative discharge and cost of ownership

Where energy feedback above 90% and a power factor of 0.99 change the operating cost of continuous pack cycling.

Request via contact form — ask for the white paper.

White paperOn request

Data integrity for regulated battery labs

Audit trails, user roles and record retention in BTS 9.1 and LIMS, for teams working toward 21 CFR Part 11 friendly workflows.

Request via contact form — ask for the white paper.

Battery testing terms

Definitions as we use them in test specifications and reports.

Cycle life
The number of charge–discharge cycles a cell completes before capacity falls to a defined end-of-life threshold, usually a percentage of its initial capacity.
C-rate
Current expressed as a multiple of a cell's rated capacity per hour. At 1C, the rated capacity would be discharged in one hour.
EIS
Electrochemical impedance spectroscopy. A small-amplitude AC signal is swept across frequencies to separate series resistance, charge-transfer and diffusion behaviour.
Formation
The first controlled charge and discharge cycles after cell assembly. They build the solid electrolyte interphase and stabilise the electrode interface.
Grading
Sorting cells by measured capacity, resistance and self-discharge after formation, so modules are built from matched cells.
Self-discharge
Capacity lost while a cell rests at open circuit. Reported as a percentage over a stated time or as a voltage drop over a stated interval.
Coulombic efficiency
The ratio of charge removed on discharge to charge added on charge, expressed as a percentage. A value below 100% indicates charge lost to side reactions.
State of charge (SoC)
Remaining capacity as a percentage of rated capacity, at a stated temperature and discharge rate.
State of health (SoH)
Present capacity or resistance relative to the beginning-of-life value, used to express degradation rather than immediate charge level.
Depth of discharge (DoD)
The fraction of rated capacity removed from a cell in a given cycle. A 100% DoD cycle uses the full usable window.
DCIR
Direct-current internal resistance. Calculated from the voltage step immediately after a current step, measured over a defined time window.
ACIR
Alternating-current internal resistance, usually measured at 1 kHz. It captures ohmic resistance but not the slower diffusion processes.
HPPC
Hybrid pulse power characterisation. A sequence of charge and discharge pulses at different states of charge, used to derive resistance and power capability.
dQ/dV
Differential capacity. The derivative of capacity with respect to voltage, used to resolve phase transitions and degradation modes.
OCV
Open-circuit voltage. The cell voltage after a defined rest period, with no current applied.
Voltage hysteresis
The difference between charge and discharge OCV at the same state of charge, caused by polarisation and material behaviour.
SEI
Solid electrolyte interphase. A passivation layer formed on the anode during the first cycles; its stability affects life and self-discharge.
N/P ratio
The ratio of negative to positive electrode capacity. It is a cell-design parameter, not a test result, but it shapes the first-cycle data.
Round-trip efficiency
Energy returned on discharge divided by energy supplied on charge. Used for cells, packs and complete storage systems.
Capacity retention
Capacity at a given cycle divided by initial capacity, expressed as a percentage. The sister metric to capacity fade.
Sampling rate
The number of measurement samples recorded per second. 10, 100 and 1000 Hz are the selectable rates on the platform described here.
Auto-ranging
Automatic selection of the narrowest current range that covers the present current, so resolution stays high without manual re-cabling.
Regenerative discharge
Returning discharge energy to the grid instead of dissipating it as heat. The feedback figure is quoted at pack level.
BMS
Battery management system. It monitors cell voltages and temperatures, balances cells and enforces limits; test systems communicate with it over CAN or SMBus.
DBC
A CAN database file describing message identifiers and signal scaling. Importing it lets the tester log named BMS signals instead of raw frames.
Thermal runaway
A self-accelerating exothermic reaction triggered by abuse, internal short or over-temperature. It requires dedicated safety testing, not a standard cycling chamber.

Document and specification questions

Are the datasheets the current revision?

Yes. The files linked here are the revisions published with this site. If a model has been revised since, ask us for the current sheet before you base a specification on it.

What does “typical, model-dependent” mean?

It means the figure is representative of the product family, not a guaranteed value for every configuration. Voltage, current, accuracy and channel count are fixed at quotation, and the quotation is the controlling document.

Can I use these figures in a tender?

You can reference them, but tender documents should use the quoted specification for the exact model, not the family-level figures on this site. Ask us for a model-specific datasheet and a compliance statement.

Do you provide a sample calibration certificate?

Yes. We can send a redacted certificate showing the as-found and as-left format, the reference standards and the uncertainty statement. The certificate for your instrument is issued after calibration.

Are CAD models or drawings available?

Outline drawings and interface dimensions are available for configured systems. Full CAD models are shared under an NDA where the project requires them. Tell us the model class and the drawing you need.

Are documents available in Spanish, French, German, Russian or Arabic?

The website is available in six languages: English, Spanish, French, German, Russian and Arabic. The official datasheets are currently issued in English; translated summaries and quotations can be provided through a regional partner on request.

Can I get an extract from a test report?

Where a relevant, non-confidential report exists, yes. Customer reports and cell data are not shared without written authorization, so we will tell you what can be released and what has to be reproduced on your own samples.

May I redistribute the datasheets?

The datasheets are NEWARE copyright. You may share them internally for evaluation. Do not republish them, alter them or present them as your own documentation without written permission.

Where can I find older revisions?

Older revisions are kept for traceability but are not published. If you need the revision that shipped with a specific instrument, send the model and serial number and we will retrieve it.

Need a document that is not listed?

Tell us the product line and the specification you need to verify. We send the current datasheet, calibration scope or test report extract where available.

Talk to an engineer

Request a quote